F10 Series Auxiliary Switches

F10 Series Auxiliary Switches

1.Rated voltage :AC 660V,DC 110V/220V
2.Rated current:10A/15A (conventional heating current), operating current 0.4A
3.Protection level:IP20
4.Product Advantages
5.‌Product Applications
ارسال درخواست
معرفی محصول

 

The FK10 series auxiliary switches are key control components designed specifically for medium- and high-voltage power systems and industrial automation scenarios. They are primarily used for the opening and closing signal control, interlocking protection, and circuit switching functions of high-voltage circuit breakers, vacuum contactors, and disconnectors. As the "signal hub" for the safe operation of power systems, this series of products ensures the accuracy of the main equipment's operating sequence through precise status feedback and reliable loop control, effectively preventing electrical accidents and providing stable protection for critical areas such as industrial power distribution and power transmission.

product-375-281

 

 
 
   NO.

1

AC 660V,DC 110V/220V

2

10A/15A (conventional heating current), operating current 0.4A

3

Multiple configurations are available, including AC 220V 10A, AC 380V 6A, and AC 660V 2A.

4

Operating force <= 16N, reset force > 0.8N, operating stroke 4mm, auxiliary stroke > 3mm

5

Relative humidity <=95% (daily average), acceleration <=15m/s², no corrosive gases

    6

7 IP20
 

  F10 series auxiliary switcheshas many advantages.

 
Utilizes silver alloy anti-oxidation contacts, possessing excellent conductivity and corrosion resistance, with a contact resistance <50mΩ, ensuring stable current transmission; the innovative self-operating planar sliding contact structure and fixed-gap design ensure consistent pressure (≥0.55N) for each pair of contacts, completely eliminating contact problems.
 
The sealed design completely isolates the contacts from the external environment, allowing stable operation in dusty and high-humidity environments; applicable temperature range covers -40℃ to +40℃, altitude <=2000m, meeting the needs of harsh industrial scenarios.
 

Employs a stacked structure, supporting adjustments to the number of contacts as needed (selectable configurations from 3NO2NC to 6NO6NC, etc.); customizable single-group contact delay function (delay gap >=0.3mm); modular housing supports quick size changes to adapt to different installation space requirements.

 

Mechanical life exceeds 3×10⁵ cycles, and electrical life exceeds 30,000 cycles. It has passed fully automated pressure testing and life verification, meeting the needs of high-frequency operation scenarios. The adaptive electromagnetic actuator ensures precise synchronization with the main switch, providing rapid and reliable response.

 

Strictly compliant with international and domestic standards such as GB/T 14048.1-2023 and IEC 60947-5-1, and certified by the ISO 9001-2000 quality system. It features overload and short-circuit protection, with a rated insulation voltage of 690V, ensuring safe operation.

 
   
 
  
‌

 

F10 series auxiliary switches has many advantages.

 

Medium and High Voltage Switchgear: As a supporting accessory for KYN28A-12 medium-voltage switchgear, vacuum circuit breakers (VCBs), and disconnectors, it enables interlocking of opening and closing and signal feedback;

01

02

03

Special Environmental Scenarios: Stable operation is achieved in dusty industrial environments such as mines, cement plants, and metallurgical plants thanks to its sealed contact design.

04

 

 
 

A

 

B

 

 

modular-1

As a specialized vacuum circuit breaker and relative accessories manufacturer in China, we have profuse designs of ABB and Siemens with series VCB, our price is very competitive because we are a manufacturer, we are the source.
We have more than 20 years of experience in this industry, main products as following:
12KV/24KV/40.5KV vacuum circuit breakers

 

 

 

تگ های محبوب: f10 series auxiliary switches, China f10 series auxiliary switches manufacturers, suppliers, factory